P.O. 215600, Jiangsu, China
info@ship-equipment.com

Marine External Fire Fighting System (FI-FI System)

FI-FI Grade: FIFI-1, FIFI-2, FIFI-3
Pump Capacity:
120~6600 m³/h
Fire Monitor Type: Electric or Manual
Medium: Foam or Sea Water
Water Monitor Capacity: ≤3600 m³/h
Foam Monitor Capacity: ≤1800 m³/h
Certificate: CCS, GL

Description

Marine External Fire Fighting System (FI-FI System) is an important fire suppression system used for fireboat, tugboat and offshore supply vessel…Thre are 3 grades of FI-FI system, FIFI-1, FIFI-2, FIFI-3, based on different requiments of ship consttruction and rules for classification.

Approval Standard:

1. Chapter 2,Part 3 of China Classification Society Rules for Classification of Sea-going Steel Ships 2018 and its Amendments.
2. IMO Chapter 14 of International Code for Fire Safety Systems and Its Amendments
3. IMO Chapter 12, <International Code for Fire Safety Systems> FSS Code

Requirements for FI-FI System

Fi-Fi system Grade FiFi-1 FiFi-2 FiFi-3
No. of Monitor 2 2 3 4 3 4
Monitor Capacity (M3/h) 1200 3600 2400 1800 3200 2400/2500
No. of Pumps 1-2 2 2-4 2 2-4
Total Pump Capacity (m3/h) 2400 7200 7200 9600 9600/10000
Throw Length(m) 120 180 150 180 150
Throw Height(m) 45 110m@70m 70 110m@70m 70

Specifications of Fire Pumps

Type Capacity
m3/h
Head
m
Speed
r/min
Engine Power
kw
CXB200-150 300 120 2100 160
CXB250-200 600 130 2100 368
CXB350-250 1200 130 1800 600
CXB400-350 1800 150 1500 1000
CXB500-400 2400 150 1500 1450
CXB600-500 4200 170 1500 3600

Specifications of Fire Monitors

Type Max. Capacity
L/min
Max. Working Pressure
Bar
Rotation Weight
kg
Throw Range
m
Horizontal Vertical
SS65 2400 16 340° +90°~ -75° 60 100
SS80 4000 16 340° +85°~ -75° 75 100
SS100 6000 16 340° +85°~ -75° 75 100
SS150 18000 16 340° +75°~ -45° 225 100
SS200 26000 16 340° +75°~ -45° 750 100
SS250 32000 16 340° +75°~ -45° 550 100
SS300 60000 16 340° +75°~ -45° 800 100

For information of external fire fighting pump.