Description
Marine External Fire Fighting System (FI-FI System) is an important fire suppression system used for fireboat, tugboat and offshore supply vessel…Thre are 3 grades of FI-FI system, FIFI-1, FIFI-2, FIFI-3, based on different requiments of ship consttruction and rules for classification.
Approval Standard:
1. Chapter 2,Part 3 of China Classification Society Rules for Classification of Sea-going Steel Ships 2018 and its Amendments.
2. IMO Chapter 14 of International Code for Fire Safety Systems and Its Amendments
3. IMO Chapter 12, <International Code for Fire Safety Systems> FSS Code
Requirements for FI-FI System
Fi-Fi system Grade | FiFi-1 | FiFi-2 | FiFi-3 | |||
No. of Monitor | 2 | 2 | 3 | 4 | 3 | 4 |
Monitor Capacity (M3/h) | 1200 | 3600 | 2400 | 1800 | 3200 | 2400/2500 |
No. of Pumps | 1-2 | 2 | 2-4 | 2 | 2-4 | |
Total Pump Capacity (m3/h) | 2400 | 7200 | 7200 | 9600 | 9600/10000 | |
Throw Length(m) | 120 | 180 | 150 | 180 | 150 | |
Throw Height(m) | 45 | 110m@70m | 70 | 110m@70m | 70 |
Specifications of Fire Pumps
Type | Capacity m3/h |
Head m |
Speed r/min |
Engine Power kw |
CXB200-150 | 300 | 120 | 2100 | 160 |
CXB250-200 | 600 | 130 | 2100 | 368 |
CXB350-250 | 1200 | 130 | 1800 | 600 |
CXB400-350 | 1800 | 150 | 1500 | 1000 |
CXB500-400 | 2400 | 150 | 1500 | 1450 |
CXB600-500 | 4200 | 170 | 1500 | 3600 |
Specifications of Fire Monitors
Type | Max. Capacity L/min |
Max. Working Pressure Bar |
Rotation | Weight kg |
Throw Range m |
|
Horizontal | Vertical | |||||
SS65 | 2400 | 16 | 340° | +90°~ -75° | 60 | 100 |
SS80 | 4000 | 16 | 340° | +85°~ -75° | 75 | 100 |
SS100 | 6000 | 16 | 340° | +85°~ -75° | 75 | 100 |
SS150 | 18000 | 16 | 340° | +75°~ -45° | 225 | 100 |
SS200 | 26000 | 16 | 340° | +75°~ -45° | 750 | 100 |
SS250 | 32000 | 16 | 340° | +75°~ -45° | 550 | 100 |
SS300 | 60000 | 16 | 340° | +75°~ -45° | 800 | 100 |
For information of external fire fighting pump.