Description
Marine fire monitors are mainly used in deck foam syetem and external FI-FI system for fireboat, tugboat, offshore supply vessel… There are two types fire monitor, water fire monitor and foam-water fire monitor with manual or electric control.
Approval Standard:
1. Chapter 1, Part 8 of China Classification Society Rules for the Classification of Sea-going Steel Ships 2018 and its Amendments
2. Chapter 14 of the International Code for Fire Safety Systems, as amended by MSC.339(91)
3. MSC.1/Circ.1431 Guidelines for the Approval of Helicopter Facility Foam Fire-fighting Appliance
4. GB 19156-2003 <General specification for fire monitors>
Specifications of Manual Water Fire Monitor
Model: |
PSC30 |
PSC40 |
PSC50 |
PSC60 |
PSC70 |
PSC80 |
PSC100 |
Rated Flow Rate |
30L/S |
40L/S |
50L/S |
60L/S |
70L/S |
80L/S |
100L/S |
Rated Working Pressure |
≤1.0 MPa |
≤1.2 MPa |
Throw Range |
≥55m |
≥60m |
≥65m |
≥70m |
≥75m |
≥80m |
≥85m |
Horizontal Rotation |
360° |
Vertical Rotation |
-40~+60° |
-60~+75° |
Main Body Material |
SUS304/SUS316 |
Connection Flange |
DN100 |
Specifications of Electric Water Fire Monitor
Model: |
PSKDC30 |
PSKDC40 |
PSKDC50 |
PSKDC60 |
PSKDC70 |
PSKDC80 |
PSKDC100 |
PSKDC120 |
Rated Flow Rate |
30L/S |
40L/S |
50L/S |
60L/S |
70L/S |
80L/S |
100L/S |
120L/S |
Rated Working Pressure |
≤0.8 MPa |
≤1.0 MPa |
≤1.2 MPa |
Throw Range |
≥55m |
≥60m |
≥70m |
≥75m |
≥80m |
≥85m |
≥90m |
≥95m |
Horizontal Rotation |
-170~+170° |
Vertical Rotation |
-60~+75°(adjustable) |
Main Body Material |
SUS304/SUS316 |
Connection Flange |
DN100 |
DN150 |
Model: |
PSKDC150 |
PSKDC180 |
PSKDC200 |
PSKDC250 |
PSKDC330 |
PSKDC420 |
PSKDC500 |
PSKDC780 |
Rated Flow Rate |
150L/S |
180L/S |
200L/S |
250L/S |
330L/S |
420L/S |
500L/S |
780L/S |
Rated Working Pressure |
≤1.4MPa |
≤1.2 MPa |
≤1.5MPa |
≤0.5MPa |
Throw Range |
≥100m |
≥105m |
≥110m |
≥115m |
≥120m |
≥160m |
≥180m |
≥45m |
Horizontal Rotation |
-170~+170° |
Vertical Rotation |
-60~+75°(adjustable) |
Main Body Material |
SUS304/SUS316 |
Connection Flange |
DN150 |
DN200 |
DN250 |
DN300 |
Specifications of Manual Foam-Water Fire Monitor
Model: |
PLC24 |
PLC32 |
PLC40 |
PLC48 |
PLC64 |
PLC80 |
PLC100 |
Rated Flow Rate |
24L/S |
32L/S |
40L/S |
48L/S |
64L/S |
80L/S |
100L/S |
Rated Working Pressure |
≤0.6 MPa |
≤1.0 MPa |
Throw Range |
Foam |
≥32m |
≥40m |
≥45m |
≥50m |
≥55m |
≥60m |
≥75m |
Water |
≥37m |
≥45m |
≥50m |
≥55m |
≥60m |
≥65m |
≥80m |
Horizontal Rotation |
360° |
Vertical Rotation |
-30~+60° |
Main Body Material |
SUS304/SUS316 |
Connection Flange |
DN80 |
DN100 |
Specifications of Electric Foam-Water Fire Monitor
Model: |
PLKDC24 |
PLKDC32 |
PLKDC40 |
PLKDC48 |
PLKDC64 |
PLKDC80 |
PLKDC100 |
PLKDC120 |
Rated Flow Rate |
24L/S |
32L/S |
40L/S |
48L/S |
64L/S |
80L/S |
100L/S |
120L/S |
Rated Working Pressure |
≤0.8MPa |
≤1.0 MPa |
≤1.2 MPa |
Throw Range |
Foam |
≥40m |
≥48m |
≥55m |
≥60m |
≥70m |
≥80m |
≥85m |
≥90m |
Water |
≥45m |
≥55m |
≥65m |
≥70m |
≥75m |
≥85m |
≥90m |
≥95m |
Horizontal Rotation |
-170~+170° |
Vertical Rotation |
-60~+75°(adjustable) |
Main Body Material |
SUS304/SUS316 |
Connection Flange |
DN100 |
DN150 |
Model: |
PLKDC150 |
PLKDC180 |
PLKDC200 |
PLKDC330 |
PLKDC420 |
Rated Flow Rate |
150L/S |
180L/S |
200L/S |
330L/S |
420L/S |
Rated Working Pressure |
≤1.4MPa |
≤1.2MPa |
Throw Range |
Foam |
≥95m |
≥100m |
≥105m |
≥80m |
≥80m |
Water |
≥100m |
≥105m |
≥110m |
≥120m |
≥140m |
Horizontal Rotation |
-170~+170° |
Vertical Rotation |
-60~+75°(adjustable) |
Main Body Material |
SUS304/SUS316 |
Connection Flange |
DN150 |
DN200 |