P.O. 215600, Jiangsu, China
info@ship-equipment.com

Marine FM200 Suppression System (HFC-227EA)

Other Name: HFC-227EA System
Application: Offshore Platform, Machinery Spaces and Cargo Pump-rooms
Fire Extinguishing Way: Total Flooding
Operation Method: Pneumatic/Manual/Electric
FM200 Cylinder Volume: ≤180L
N2 Cylinder Volume: 4L
Certificate: CCS, NK, GL

Description

Marine FM200 suppression system is designed and produced according to MSC/Circ.848 <Revised Guidelines for the Approval of Equivalent Fixed Gas Fire-Extinguishing Systems, as Referred to in SOLAS 74, for Machinery Spaces and Cargo Pump-rooms>.

Approval Standard:

1. Chapter 5 of International Code for Fire Safety Systems, as Amended by MSC.206(81) and MSC. 339(91)
2. MSC/Circ.848 Revised Guidelines for the Approval of Equivalent Fixed Gas Fire-Extinguishing Systems, as Referred to in SOLAS 74, for Machinery Spaces and Cargo Pump-rooms.
3. MSC.1/Circ.1267 Amendments to Revised Guidelines for the Approval of Equivalent Fixed Gas Fire-Extinguishing Systems, as Referred to in SOLAS 74, for Machinery Spaces and Cargo Pump-Rooms(MSC/CIRC.848).

Specification:

Model: CQMQ2.5 CQMQ4.2
Nominal Working Pressure: 2.5MPa 4.2MPa
Max. Working Pressure: 4.2MPa 5.3MPa
Min. Working Pressure: 2.0MPa 3.6MPa
FM200 Cylinder Volume: 10、20、30、40、70、90、120、150、180 (L)
N2 Pilot Cylinder Volume: 4 (L)
Max. Vertical Installation Distance: ≤6.5 (m)
Operation Method: Pneumatic/Manual/Emergency Manual
Electric/Manual/Emergency Manual
Filling Rate: ≤0.95kg/L (welded steel gas cylinder) ≤1.12kg/L (seamless steel gas cylinder)
≤1.12kg/L (seamless steel gas cylinder)
Design Concentration of

Extinguishing Agent (Volume)

8.6%(Class B fires)

10%(Class A fires)

Main Components: Cylinders and Fame Assembly, Control Box, Selecting(Release Valve, Quick Opening Valve), Gas one-Way Valve, Nozzle, Fire Alarm Board, Visual and Audio Alarm