Description
Marine fixed deck foam fire extinguishing system is to be designed for extinguishing fire on deck for chemical vessels or oil tankers with low expansion foam. There are two major systems, foam bladder tank proportioning system and balanced pressure proportioning system.
The Low Expansion Foam fire extinguishing system uses a non-toxic foam concentrate, water and air to effectively extinguish fires in open spaces. The system provides safe and effective protection, and is harmless to the crew and environment.
Approval Standard:
1. Chapter 6 of International Code for Fire Safety Systems, as Amended by MSC. 327(90) and Chapter 14 of International Code for Fire Safety Systems, as Amended by MSC. 339(91).
2. GB20031-2005 The Articles 5.1 of General technical specifications for foam fire extinguishing systems and components.
Specifications of Bladder Tank Type
Type: | Foam Bladder Tank Proportioning System | ||
Model: | Tank Volume (m³) | Flow Rate (L/S) | |
Horizontal Tank | PHYM32-XX-V | 0.5/0.7/1.0/1.5/2.0/2.5/3.0/3.5/4.0/4.5/5.0 | 8~32/16~48/24~64/48~96 |
PHYM48-XX-V | 1.0/1.5/2.0/2.5/3.0/3.5/4.0/4.5/5.0/5.5/6.0/
6.5/7.0/7.5/8.0/9.0/10.0 |
||
PHYM64-XX-V | 1.0/1.5/2.0/2.5/3.0/3.5/4.0/4.5/5.0/5.5/6.0/
6.5/7.0/7.5/8.0/9.0/10.0 |
||
PHYM80-XX-V | 1.0/1.5/2.0/2.5/3.0/3.5/4.0/4.5/5.0/5.5/6.0/
6.5/7.0/7.5/8.0/9.0/10.0 |
||
Vertical Tank | PHYM32-XX-H | 0.5/0.7/1.0/1.5/2.0/2.5/3.0 | |
PHYM48-XX-H | 1.0/1.5/2.0/2.5/3.0 | ||
PHYM64-XX-H | 1.0/1.5/2.0/2.5/3.0 | ||
Working Pressure Range (MPa) | 0.5-1.2 | ||
Ratio of Mixture | 3%,6% AFFF | ||
Material of Tank | Q345R | ||
Remark | XX means Tank Volume |
Specifications of Balanced Pressure Type
Type: | Balanced Pressure Proportioning System | |
Model: | Tank Volume (m³) | Flow Rate (L/S) |
PHP-3 | 0.3 | 8~32/16~48/24~64/48~96 |
PHP-5 | 0.5 | |
PHP-7 | 0.7 | |
PHP-10 | 1.0 | |
PHP-15 | 1.5 | |
PHP-20 | 2.0 | |
PHP-25 | 2.5 | |
PHP-30 | 3.0 | |
Working Pressure Range (MPa) | 0.5-1.2 | |
Ratio of Mixture | 3%,6% AFFF | |
Material of Tank | Q345R or 316L |